Installation of cathodic protection
rectifier transformer
Installing the rectifier transformer The installation of the rectifier transformer on the foundation is done according to the following steps: a reinforced concrete foundation with dimensions of 30 x 100 x 150 cm inside ...
Cathodic protection cables
Additional equipment of cathodic protection systems / Cathodic protection cables: Cables used in cathodic protection systems are usually single-stranded semi-transparent (7 strands) with facing covers...
Coke Breeze
Accessories for cathodic protection systems / petroleum coking coal and metallurgy: current injection anodes are usually installed in horizontal anode beds (when there are no environmental restrictions) or anode beds…
Joints (Splice Kit)
Accessories of cathodic protection systems / Joints: Joints are used to insulate the branching of cables of the cathodic protection system (such as surface beds, wells, cable connection to the network...
Earthing equipment
Additional equipment for cathodic protection systems / earthing equipment: For cathodic protection stations with rectifier transformers, a separate earthing system is considered. The earthing system of the ...
Primer and handi cap
Auxiliary equipment of cathodic / primer and handi cap protection systems: places where the cable is connected to the structure under protection and is buried in the electrolyte, due to the current flux...
Pin brazing cable connection
Auxiliary equipment of cathodic protection systems / cable connection by pin brazing method to connect the cable to the structure under protection such as pipelines, it is possible to use the pin method...
Thermal welding
Auxiliary equipment of cathodic protection systems / thermal welding: thermal welding is commonly used to connect the cable to the structure under cathodic protection. So in order to do this…
Coupon polarization
Coupon polarization is a device used to measure the level of polarization potential. Coupon polarization consists of a box that usually...
Zinc reference electrode
Pure zinc electrodes can be used to measure the potential of structures inside the electrolyte. Of these half-piles, due to their long life ...
Reference electrodes
To check the performance of cathodic protection systems, there are various measuring equipment and instruments ...
Silver/silver chloride reference
electrode
This half cell is made of a platinum electrode with a silver coating. The solution used is saturated KCl or 3.5 M KCl solution. From…
Copper/copper sulfate
reference electrode
Copper / Copper Sulfate Reference Electrode: This half cell consists of a pure copper rod in a saturated solution of copper sulfate. of copper/copper sulfate half-cell for the size of…
Power distribution board of
cathodic protection station
Due to the fact that rectifier transformers are installed outside the electricity distribution buildings and it is also possible to install several rectifier transformers inside a station...
Groundbed Marker
The appearance of the anode substrate marker is the same as the post marker test, with the difference that there is no place to connect the cable. indicating the …
Postmarker test
Post Marker Test Post Marker Test is used to measure the protection potential of the structure under protection. Test post markers are usually made of carbon steel...
Current Control Box
Current Control Box (Current Control Box) Current Control Box is like a distribution box, with the difference that a variable resistor is installed inside. The dimensions of the ...
Junction Box
Junction box: Junction boxes are one of the main components of sacrificial cathodic protection systems and current injection. In the pipeline cathodic protection system,...